Global website
Home page
Change division
Industrial & Automotive Auto Refinishing

Ransburg RCS 2 Ratio Control System

The RCS2 provides absolute on-ratio gear-driven mixing and metering control

Fast and reliable, the RCS 2 is the ideal choice for applications where short trigger times, quick response, and/or low flow are required. The RCS 2 features magnetically coupled metering pumps that eliminate shaft seal leaks.

Ransburg RCS 2 Ratio Control System - Carlisle Fluid Technology
  • Overview
  • Tech Specs
  • Literature
  • Product Manuals
  • Materials
  • Markets
  • Part Numbers
Overview

Overview

Accurate, consistent proportioning:

Ransburg RCS 2 software provides user-friendly programmable alarm tolerances, programmable pot-life timer, multiple flow rates and ratios, and no exotic mixing chambers to maintain or external fluid boosters or balancing pumps required. 

Magnetically coupled fluid metering pumps

RCS 2 technology has an established record for reliability in high performance finishing systems. With no critical seals to worry about leaking or maintaining, you get trouble-free on-ratio performance year after year. 

Flushable color pump:

RCS 2 is specifically designed to accommodate color to color changes with no color carryover.

Modular color changer with air/solvent purge:

RCS 2 offers a graphical display for optimizing color change, flush, and load sequences. Different sequences and times can be programmed for every color (parameter set).

Ultimate system flexibility

RCS 2 can be used with rotary atomizers, bells, disks and either electrostatic or non-electrostatic sprayguns. The system can be configured as a stand-alone cart-mounted assembly, as individual control panels for integration into an existing paint shop, or the control racks and boards can be mounted in an engineered control panel.

Programmable Gun Types

RCS 2 can be easily integrated into either automatic or manual multi-applicator systems. System can be configured for flow and ratio control for automatic guns or ratio only mode for manual or hand gun applications.

RCS 2 is the latest generation Ratio Control System which establishes a new standard for precise electronically controlled gear-pump metering.

Fast and reliable, the RCS 2 is the ideal choice for applications where short trigger times, quick response, and/or low flow are required. RCS 2 features magnetically coupled metering pumps that eliminate shaft seal leaks.

The RCS 2 provides absolute on-ratio gear-driven mixing and metering control. The system can be used with solvent borne or waterborne materials. This makes for easy integration into automatic or manual systems using single or multiple applicators.

Technical Specifications

Technical Specifications

Ransburg RCS 2 Ratio Control System

Size 71H x 25W x 32D
Weight 400lbs
Operating Temperature 32 degrees F - 130 degrees F
Operating Humidity 0% - 95%
Pneumatic Air Consumption Less than 5cfm
Pneumatic Inlet and Outlet Size 3/8 ODT
User Interface Processor 1GHz Intel PIII running Windows embedded XP
Control Processor Motorola MC68HC16
Fluid Capacity 0.9cc/min - 1500 cc/min per pump
Fluid Inlet Size 3/8 ODT
Fluid Viscosity Range 20 - 1000 centipose
Fluid Input Pressure 3 - 120 psi
Fluid Outlet Pressure 200 psi max
Literature

Literature

Ransburg RCS 2 Ratio Control System (Sales Literature IL-8914-A) - Carlisle Fluid Technology

Ransburg RCS 2 Ratio Control System (Sales Literature IL-8914-A)

Sales Literature for RCS 2 Ratio Control System (Sales Literature IL-8914-A)

Show literature
Product Manuals

Product Manuals

Ransburg Servo Amplifier (Serv. Man. LN-9405-00.1) - Carlisle Fluid Technology

Ransburg Servo Amplifier (Serv. Man. LN-9405-00.1)

Service Manual for RCS 2 Interface (Serv. Man. LN-9405-00.1)

Show literature
Ransburg RCS2 Ribbon Cable Install (Serv. Ins. (SI-09-10) - Carlisle Fluid Technology

Ransburg RCS2 Ribbon Cable Install (Serv. Ins. (SI-09-10)

Service Manual for RCS2 Ribbon Cable Install (Serv. Ins. (SI-09-10)

Show literature
Ransburg RCS Pump Bolt Install. (Serv. Ins. SI-09-06.1) - Carlisle Fluid Technology

Ransburg RCS Pump Bolt Install. (Serv. Ins. SI-09-06.1)

Service Manual for RCS Pump Bolt Install. (Serv. Ins. SI-09-06.1)

Show literature
Ransburg RCS 2 Parts, Maintenance, And Troubleshooting (Serv. Man. LN-9408-06.3) - Carlisle Fluid Technology

Ransburg RCS 2 Parts, Maintenance, And Troubleshooting (Serv. Man. LN-9408-06.3)

Service Manual for RCS 2 Parts, Maintenance, And Troubleshooting (Serv. Man. LN-9408-06.3)

Show literature
Ransburg RCS Positive Displacement Pump (LN-9415-02) - Carlisle Fluid Technology

Ransburg RCS Positive Displacement Pump (LN-9415-02)

Service Manual for RCS Positive Displacement Pump

Show literature
Ransburg RCS 2 User Manual (Serv. Man LN-9407-00.3) - Carlisle Fluid Technology

Ransburg RCS 2 User Manual (Serv. Man LN-9407-00.3)

RCS 2 User Manual (Serv. Man LN-9407-00.3)

Show literature
Ransburg RCS-2 RIO Interface Programmers Manual (Serv. Man. LN-9409-03.2) - Carlisle Fluid Technology

Ransburg RCS-2 RIO Interface Programmers Manual (Serv. Man. LN-9409-03.2)

RCS-2 RIO Interface Programmers Manual (Serv. Man. LN-9409-03.2)

Show literature
Ransburg Updating Firmware/Software (Serv. Ins. SI-09-04.1) - Carlisle Fluid Technology

Ransburg Updating Firmware/Software (Serv. Ins. SI-09-04.1)

Service Instruction for Updating Firmware/Software (Serv. Ins. SI-09-04.1)

Show literature
Ransburg RCS Start Up Requirements (Serv. Ins. SI-08-16.1) - Carlisle Fluid Technology

Ransburg RCS Start Up Requirements (Serv. Ins. SI-08-16.1)

Service Instruction for RCS Start Up Requirements (Serv. Ins. SI-08-16.1)

Show literature
RANSBURG RCS 2 RATIO CONTROL SYSTEM Install of Shaft Seals (SI-17-02) - Carlisle Fluid Technology

RANSBURG RCS 2 RATIO CONTROL SYSTEM Install of Shaft Seals (SI-17-02)

RANSBURG RCS 2 RATIO CONTROL SYSTEM Install of Shaft Seals

Show literature
RANSBURG RCS 2 Catalyst Flow Sensor Alarm Service Instruction (SI-17-05) - Carlisle Fluid Technology

RANSBURG RCS 2 Catalyst Flow Sensor Alarm Service Instruction (SI-17-05)

RANSBURG RCS 2 Catalyst Flow Sensor Alarm Service Instructions

Show literature
Materials

Materials

For use on the materials below:

  • Metal
  • Wood
  • Plastic
  • Ceramic
  • Other Substrates
  • Primer
  • Base Coat
  • Clear Coat
Markets

Markets

  • Automotive OEM & Tier 1&2
Part Numbers

Part Numbers

RCS